Koppeltaal 2.0 Implementation Guide (Full Documentation)
1.4.5-beta.002 - ci-build
Koppeltaal 2.0 Implementation Guide (Full Documentation) - Local Development build (v1.4.5-beta.002) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Official URL: http://koppeltaal.nl/fhir/StructureDefinition/KT2Device | Version: 1.4.5-beta.002 | |||
Draft as of 2023-02-07 | Computable Name: KT2_Device | |||
Copyright/Legal: VZVZ |
The (FHIR) Device (resource) is a representation of an application that is used in the provision of healthcare without being substantially changed through that activity. The device may be a module, portal or eHealth app.
Usages:
You can also check for usages in the FHIR IG Statistics
Description of Profiles, Differentials, Snapshots and how the different presentations work.
Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
---|---|---|---|---|
![]() ![]() |
0..* | Device | Item used in healthcare | |
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() |
0..* | Reference(KT2_Device) | Extension URL: http://koppeltaal.nl/fhir/StructureDefinition/resource-origin | |
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() |
1..* | Identifier | Instance identifier | |
![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Fixed Value: http://vzvz.nl/fhir/NamingSystem/koppeltaal-client-id |
![]() ![]() ![]() |
?!Σ | 1..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. |
![]() ![]() ![]() |
1..* | BackboneElement | The name of the device as given by the manufacturer | |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Fixed Value: user-friendly-name | |
![]() ![]() ![]() |
0..1 | Reference(KT2_Organization) | Organization responsible for device | |
![]() |
Path | Conformance | ValueSet / Code | URI |
Device.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 From the FHIR Standard | |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 From the FHIR Standard | |
Device.deviceName.type | required | Fixed Value: user-friendly-namehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 From the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from Device
Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
---|---|---|---|---|
![]() ![]() |
Device | |||
![]() ![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() |
0..* | Reference(KT2_Device) | Extension URL: http://koppeltaal.nl/fhir/StructureDefinition/resource-origin | |
![]() ![]() ![]() |
1..* | Identifier | Instance identifier | |
![]() ![]() ![]() ![]() |
0..1 | uri | The namespace for the identifier value Fixed Value: http://vzvz.nl/fhir/NamingSystem/koppeltaal-client-id | |
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
1..1 | code | active | inactive | entered-in-error | unknown | |
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
1..* | BackboneElement | The name of the device as given by the manufacturer | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Fixed Value: user-friendly-name | |
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..1 | Reference(KT2_Organization) | Organization responsible for device | |
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() |
Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
---|---|---|---|---|---|---|---|---|
![]() ![]() |
0..* | Device | Item used in healthcare | |||||
![]() ![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
0..* | Reference(KT2_Device) | Extension URL: http://koppeltaal.nl/fhir/StructureDefinition/resource-origin | |||||
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() |
1..* | Identifier | Instance identifier | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Fixed Value: http://vzvz.nl/fhir/NamingSystem/koppeltaal-client-id | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() |
?!Σ | 1..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
![]() ![]() ![]() |
1..* | BackboneElement | The name of the device as given by the manufacturer | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Fixed Value: user-friendly-name | |||||
![]() ![]() ![]() |
0..1 | CodeableConcept | The kind or type of device Binding: DeviceType (example): Codes to identify medical devices. | |||||
![]() ![]() ![]() |
0..1 | Reference(KT2_Organization) | Organization responsible for device | |||||
![]() |
Path | Conformance | ValueSet / Code | URI | |||
Device.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languages From the FHIR Standard
| ||||
Device.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 From the FHIR Standard | ||||
Device.identifier.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-type From the FHIR Standard | ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 From the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 From the FHIR Standard | ||||
Device.deviceName.type | required | Fixed Value: user-friendly-namehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 From the FHIR Standard | ||||
Device.type | example | DeviceTypehttp://hl7.org/fhir/ValueSet/device-type From the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from Device
Key Elements View
Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
---|---|---|---|---|
![]() ![]() |
0..* | Device | Item used in healthcare | |
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() |
0..* | Reference(KT2_Device) | Extension URL: http://koppeltaal.nl/fhir/StructureDefinition/resource-origin | |
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() |
1..* | Identifier | Instance identifier | |
![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Fixed Value: http://vzvz.nl/fhir/NamingSystem/koppeltaal-client-id |
![]() ![]() ![]() |
?!Σ | 1..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. |
![]() ![]() ![]() |
1..* | BackboneElement | The name of the device as given by the manufacturer | |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Fixed Value: user-friendly-name | |
![]() ![]() ![]() |
0..1 | Reference(KT2_Organization) | Organization responsible for device | |
![]() |
Path | Conformance | ValueSet / Code | URI |
Device.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 From the FHIR Standard | |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 From the FHIR Standard | |
Device.deviceName.type | required | Fixed Value: user-friendly-namehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 From the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
Differential View
This structure is derived from Device
Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
---|---|---|---|---|
![]() ![]() |
Device | |||
![]() ![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() |
0..* | Reference(KT2_Device) | Extension URL: http://koppeltaal.nl/fhir/StructureDefinition/resource-origin | |
![]() ![]() ![]() |
1..* | Identifier | Instance identifier | |
![]() ![]() ![]() ![]() |
0..1 | uri | The namespace for the identifier value Fixed Value: http://vzvz.nl/fhir/NamingSystem/koppeltaal-client-id | |
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
1..1 | code | active | inactive | entered-in-error | unknown | |
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
1..* | BackboneElement | The name of the device as given by the manufacturer | |
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Fixed Value: user-friendly-name | |
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..1 | Reference(KT2_Organization) | Organization responsible for device | |
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() |
0..0 | |||
![]() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
---|---|---|---|---|---|---|---|---|
![]() ![]() |
0..* | Device | Item used in healthcare | |||||
![]() ![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
0..* | Reference(KT2_Device) | Extension URL: http://koppeltaal.nl/fhir/StructureDefinition/resource-origin | |||||
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() |
1..* | Identifier | Instance identifier | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Fixed Value: http://vzvz.nl/fhir/NamingSystem/koppeltaal-client-id | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() |
?!Σ | 1..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
![]() ![]() ![]() |
1..* | BackboneElement | The name of the device as given by the manufacturer | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Fixed Value: user-friendly-name | |||||
![]() ![]() ![]() |
0..1 | CodeableConcept | The kind or type of device Binding: DeviceType (example): Codes to identify medical devices. | |||||
![]() ![]() ![]() |
0..1 | Reference(KT2_Organization) | Organization responsible for device | |||||
![]() |
Path | Conformance | ValueSet / Code | URI | |||
Device.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languages From the FHIR Standard
| ||||
Device.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 From the FHIR Standard | ||||
Device.identifier.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-type From the FHIR Standard | ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 From the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 From the FHIR Standard | ||||
Device.deviceName.type | required | Fixed Value: user-friendly-namehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 From the FHIR Standard | ||||
Device.type | example | DeviceTypehttp://hl7.org/fhir/ValueSet/device-type From the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from Device